· Esophageal Pressure · More than 40
Parameters · 5 Signals · 3 Loops · Stress Index · PTP Plot · · Tendency Graph · Pimax - Pemax - P0,1
Measurement · Signals Records |
|
|
|
|
||
|
|
FLUXMED GrE The most complete
version of the equipment. FluxMed GrE is the top-of-the-line version. With its esophageal measuring capabilities it makes complete patient evaluation and assessment possible. Every patient in the process of weaning should have their esophageal pressure monitored, especially COPD patients. It is a fundamental tool for use in intensive care units, pulmonary laboratories, sleep laboratories, doctor surgeries. Esophageal
Pressure The measurement of esophageal pressure makes it possible to measure the most relevant parameters in the quantification of the effort done by the respiration muscles, in mechanically ventilated patients. A patient’s ineffective respiratory efforts can be detected, and autoPEEP measured. Ventilated
Patients FluxMed GrE respiratory mechanics monitor can be
directly connected to an intubated and ventilated patient in assisted or
controlled ventilation, enabling a detailed analysis of synchronicity between
the patient and the respirator. Flow Sensor Thanks to being able
to perform a proximal measurement, it avoids the error produced by the
distensibility of the respirator tubes. Non-Invasive
Ventilation (VNI) It is particularly
useful for monitoring ventilated patients in a non-invasive way. The flow
sensor easily adapts to face masks making it possible to monitor patients
with CPAP or BIPAP. Spontaneous
Respiration By connecting the
flow sensor to a mask, spontaneous-breathing patients can be monitored, thus
easily obtaining accurate readings of the patient’s condition, making
it possible to objectively choose whether there is a need to intubate and
mechanically assist breathing. It allows for a thorough follow-up of the
patient. Weaning FluxMed GrE respiratory mechanics monitor shows the
most important parameters on screen to help determine the success of a
patient’s weaning. It makes it possible to carefully carry out a
patient’s follow-up, in his process of not needing further respiratory
assistance. Proximal Sensor The proximal flow
sensor eliminates readings error caused by the distensibility of the
respirator’s hoses, thus making the readings more accurate. PC Connectivity FluxMed GrE respiratory mechanics monitor comes with an
USB data transfer connector, making it possible to record long lasting
examinations with measurements and tendencies in the calculated parameters. |
|